complete with electric ignition and flame failure controls wired with continuous running fan

The waste will be reduced by 90~95% to leave 10 -5% ash  
2.4 Quality/Environmental Standards  
NEMA ACT (EMCA) 1999 BS3316  
2.5 Operating Period  
Anticipated daily operating period 8 hours  
Maximum operating period 12 hours  
2.6 Chamber  
Should be refractory lined to the following standard; Hearth and lower section of chamber walls  
2.7 Hot face material  
Super duty firebrick  
Limiting continuous service limit 1500°C  
Thickness 100mm  
Thermal conductivity 1.3 W/mk  
2.8 Insulation  
Calcium silicate  
Limiting continuous service limit 1000°C  
Thickness 25mm  
Should be manufactured from refractory lined mild steel or high quality air-cooled stainless steel. The chimney/stack should have a minimum 
height of 10 meters above ground level.   
2.10  Ignition Burners  
Fully packaged oil type, complete with electric ignition and flame failure controls, wired with continuous running fan and complete with all 
valves, fan and motor.  
•         Maximum rating:            at least 450kW/hour  
•         Burner:                            arranged for on/off operation  
•         Maximum consumption: at least 6 litres/hour  
•         Average consumption:    at least 3 litres/hour  
2.11 Afterburner  
Fully packaged oil type, complete with electric ignition and flame failure controls wired with continuous running fan and complete with all 
valves, fan and motor.  
Maximum rating: at least 450kW/hour  
Burner: arranged for on/off operation  
Maximum consumption: at least 9 litres/hour  
Average consumption: at least 4.5 litres/hour  
2.12 Flue gas treatment  
Should have particulate remover (scrubbers)